Model: NF 1.100 FT.18S

0.2-1.3 LPM 58 PSI PTFE Head LIQUIPORT® Liquid Transfer Pump w/Manual Control

  • Flow range up to 1.3 L/min
  • Simple, intuitive operation
  • Fluoropolymer flow path for high chemical resistance
  • Maintenance–free, compact design
This pump is suitable for the following applications :
  • Liquid Transfer
Please Note: While other models may fit your application, this pump was chosen as the best match of materials, compatibilities, and cost. To discuss other options, please contact KNF.
KNF LIQUIPORT diaphragm pumps offer a variety of options to suit most laboratory liquid transfer needs. The high pressure NF 1.100 FT.18S version has a flow range of 0.2 – 1.3 L/min and is constructed with the following chemically-resistant fluoropolymer flow path materials: PTFE head, PTFE diaphragm, and FFKM valves. This pump offers manual control through a control knob.
All LIQUIPORT pumps are simple to operate, compact, and quiet, making them a welcome addition to any business or academic lab. With a durable and IP65 splash-proof design, these pumps are maintenance free, and provide trouble-free ±1% repeatability performance. LIQUIPORT pumps are self-priming up to 9.8 feet of water, and can run dry indefinitely without damage.  Also, unlike peristaltic pumps, there are no troublesome tubing to break or fatigue.
Always check the compatibility of flow path materials with the specific chemicals that will come in contact with your pump.
LIQUIPORT Liquid Transfer Pump Testimonial

The machine in question has a working life of eight to ten years, with the pumps working several hours each day, providing continuous flow of liquids between different baths, so durability is a very important factor. We had used KNF pumps for other projects and were happy with their robustness and longevity so, when two of the four original pumps failed after just two years, we replaced them with the LIQUIPORT pumps. Another useful feature is that the LIQUIPORT pumps have electronic control of the flow rate, whereas the original pumps could only be adjusted mechanically. KNF was also able to modify the pumps specifically for us so that our pumps restart automatically as soon as the whole machine is started. We will almost certainly buy more LIQUIPORTS to replace the other two original pumps in the machine.

- Thomas Würtz, System Engineer, Mettler-Toledo

  • Liquid Flow Rate, L/min0.2 - 1.3
  • Weight, lbs. (kg)2.2 (1)
  • Connection Tubing ID, in. (mm)5/16 (8)
  • Permissible Liquid Media Temp Range, °C5 to 80
  • Pump HeadPTFE
  • DiaphragmPTFE covered
  • ValvesFFKM
  • Dimensions L x H x W, in. (mm)5.2 x 7.0 x 3.9 (130 x 177 x 99)
  • Maximum Suction9.8 ft H20
  • Maximum Pressure, psig (bar)58 (4)
VWR InternationalCall:(800) 932-5000www.vwr.com Buy Now
Ace Glass Inc.Call:(800) 223-4524www.aceglass.com
Government Scientific SourceCall:(800) 248-8030www.govsci.com
Midland ScientificCall:(800) 642-5263www.midlandsci.com
SECO-Scientific EquipmentCall:(800) 770-7326www.seco.us
Spectrum Chemicals and Laboratory ProductsCall:(800) 813-1514www.spectrumchemical.com
Thomas ScientificCall:(800) 345-2100www.thomassci.com
Wilkem ScientificCall:(800) 766-5676www.wilkem.com